Slide 1 Slide 2 Slide 3 Slide 4 Slide 5 Slide 6 Slide 7 Slide 8 Slide 9 Slide 10 Slide 11 Slide 12 Slide 13 Slide 14 Slide 15 Slide 16 Slide 17 Slide 18 Slide 19 Slide 20 Slide 21 Slide 22 Slide 23 Slide 24 Slide 25 Slide 26 Slide 27 Slide 28 Slide 29 Slide 30 Product List
HotSwap-Slide25

So the time it takes for a short circuit to be controlled is dependent on the controller internal delays, MOSFET Total Gate charge, and the controller Gate Pulldown Current. Following the propagation delay, the time taken for the controller to control the current is represented by tGATEOFF = Q / IGATEPULLDOWN.

PTM Published on: 2008-04-29