In single shot mode the ADC conversion samples the signal on the input channel, minimum of 1uS sample time. The sample and hold amplifier then changes for a minimum of .5uS and the conversion will take 13 ADCLK cycles. As stated earlier the PWM module can control the ADC conversion enabling sampling of average current or peak currents.