Now to the combined operation modes; in these modes at least two of the channels of one timer array unit are used together or combined. The simplest mode of these combined operation modes is the “PWM output mode”. In PWM mode, one channel of the TAU is used in master mode to determine the period of the PWM signal. The second channel, operating in what is called slave mode, is used to determine the duty cycle of the PWM signal.