VBO is the breakdown voltage of the SIDACtor device. When VBO is applied to the device, it switches into the crowbar state. Between VDRM and VBO, a SIDACtor device will behave much like a TVS diode clamping device. VBO varies considerably from device to device and will increase slightly as the device’s temperature is increased.