Slide 1 Slide 2 Slide 3 Slide 4 Slide 5 Slide 6 Slide 7 Slide 8 Slide 9 Slide 10 Slide 11 Slide 12 Slide 13 Slide 14 Product List
ISL8500x-Slide10

In fault conditions where the output voltage is lifted above its setting point, reverse current will be forced into the inductor and low-side MOSFET. When the inductor current exceeds the reverse current limit, the low-side FET is turned off to prevent damage to the MOSFET.

PTM Published on: 2017-08-30