The UCC28070 also has a current synthesis function that removes the need for two additional current sense transformers. It synthesizes the downward slope (dashed red portion of waveform) eliminating the need for transformers to capture the actual downward current slope. This current synthesis capability is another system cost reduction feature of the UCC28070.