The effectiveness of noise attenuation is undoubtedly the primary concern for selecting an EMI Filter. Insertion Loss in decibels is derived as, twenty times Log to the base 10 of V1 divided by V2, where V1 is the EMI voltage without the filter and V2 is the EMI voltage with the filter.