Slide 1 Slide 2 Slide 3 Slide 4 Slide 5 Slide 6 Slide 7 Slide 8 Slide 9 Slide 10 Slide 11 Slide 12 Slide 13 Slide 14 Slide 15 Slide 16 Slide 17 Slide 18 Slide 19 Slide 20 Slide 21 Slide 22 Slide 23 Slide 24 Slide 25 Slide 26 Slide 27 Slide 28 Slide 29 Slide 30 Slide 31 Slide 32 Slide 33 Slide 34 Slide 35 Slide 36 Slide 37 Slide 38 Product List
Limitations of Saturation Flux Density Image of Fair-Rite Products Corp Limitations of Saturation Flux Density Charts

There are limitations of flux density saturation. In order to set a standard to rate all of the company’s materials and products, all the materials developed and in development are tested on a standard size toroid at 10 kHz. This allows engineers to develop a standard to rate the products for different applications. So, at higher frequencies, core saturation will shift and core loss becomes a larger constraint on design than flux density saturation. As seen here, Fair-Rite’s 79 material is limited to 1,500 gauss at 300 kHz before core loss becomes too great and goes into thermal shock.