Slide15

In a DC-DC converter with repeated switching of a short duration, the discharging does not complete within the switch OFF time and charge remains in the electrolytic capacitor. As a result, the voltage does not sufficiently decrease, distortions occur in the voltage waveform, and the output becomes unstable, which does not allow for favorable ripple control.