For solar cell charging applications, the LTM8062 ensures that the maximum available power is drawn from the source with its integrated maximum peak power tracking circuit. By simply using a resistor divider, the charge current is automatically adjusted to maintain the input voltage at the peak power point of the solar cell. Refer to the solar cell’s datasheet to determine the peak power voltage.