Current/Voltage Transducer Monitors

Results: 10
Manufacturer
CR Magnetics Inc.Verivolt LLC
Series
CR4500Entube SEIsoBlock I-FGIsoBlock V
Type
Current TransducerTrue RMS AC Voltage TransducerVoltage Transducer
Input Range
0 ~ 15A0 ~ 250VAC0 ~ 25A0 ~ 6A±50V±100V±500V±1000V±1500V
Output
0 ~ 5VDC±5V±10V
Isolation
1200V (Working)1500V (Working)2500VDC-
Response Time
2.8µs5µs250ms-
Accuracy
±0.2%0.5%
Voltage - Supply
8 ~ 28VDC9 ~ 28VDC24VDC-
Termination Style
Screw TerminalSpring Terminal
Operating Temperature
-25°C ~ 70°C0°C ~ 60°C
Approval Agency
-CE, cURus
Stocking Options
Environmental Options
Media
Marketplace Product
10Results

Showing
of 10
Compare
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Type
Input Range
Output
Isolation
Response Time
Accuracy
Voltage - Supply
Mounting Type
Termination Style
Operating Temperature
Approval Agency
IsoBlock V-1C
ISOBLOCK V-1C (1000V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
113
In Stock
1 : ¥2,745.89000
Box
Box
Active
Voltage Transducer
±1000V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock V-1C
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
65
In Stock
1 : ¥2,745.89000
Box
Box
Active
Voltage Transducer
±1500V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock I-FG-1C
ISOBLOCK I-FG-1C (6A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
13
In Stock
1 : ¥1,742.58000
Box
Box
Active
Current Transducer
0 ~ 6A
±10V
1200V (Working)
5µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
CR4510-250,CR4510-500
CR4510-250
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
10
In Stock
1 : ¥1,782.54000
Box
Box
Active
True RMS AC Voltage Transducer
0 ~ 250VAC
0 ~ 5VDC
2500VDC
250ms
0.5%
24VDC
DIN Rail
Screw Terminal
0°C ~ 60°C
CE, cURus
IsoBlock V-1C
ISOBLOCK V-1C (500V 10V)
TRANSDUCER VOLTAGE 8-28VDC
Verivolt LLC
23
In Stock
1 : ¥2,745.89000
Box
Box
Active
Voltage Transducer
±500V
±10V
1500V (Working)
2.8µs
±0.2%
8 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock V-1C
ISOBLOCK V-1C (50V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
15
In Stock
1 : ¥2,745.89000
Box
Box
Active
Voltage Transducer
±50V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock V-1C
ISOBLOCK V-1C (100V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
4
In Stock
1 : ¥2,745.89000
Box
Box
Active
Voltage Transducer
±100V
±10V
1500V (Working)
2.8µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock I-FG-1C
ISOBLOCK I-FG-1C (15A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
8
In Stock
1 : ¥1,742.58000
Box
Box
Active
Current Transducer
0 ~ 15A
±10V
1200V (Working)
5µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
IsoBlock I-FG-1C
ISOBLOCK I-FG-1C (25A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
7
In Stock
1 : ¥1,742.58000
Box
Box
Active
Current Transducer
0 ~ 25A
±10V
1200V (Working)
5µs
±0.2%
9 ~ 28VDC
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
ENTUBE SE
ENTUBE SE (100V 5V)
TRANSDUCER VOLTAGE DIVIDER
Verivolt LLC
1
In Stock
1 : ¥1,974.41000
Box
Box
Active
Voltage Transducer
±100V
±5V
-
-
±0.2%
-
DIN Rail
Spring Terminal
-25°C ~ 70°C
-
Showing
of 10

Current/Voltage Transducer Monitors


Industrial current or voltage transducers are used to monitor variable or non-sinusoidal sources, trigger peripheral devices in phase-fired control systems, monitor ground current, and other voltage or current monitoring applications. Output types include analog voltage or current, and positive and negative fixed voltages with accuracy from 0.2 to 2%.