Latching Form B Reed Relays Overview Slide 13

With the contacts in the open state, a 1.5 millisecond nominal voltage pulse with the correct voltage polarity is applied to the latching coil. This voltage pulse will create a magnetic field from the coil windings of the latching coil that is an aiding field to the permanent magnet, and thereby closing the contacts.

PTM Published on: 2011-02-10