FHS-Slide6

The Minisens is designed to sit atop the current-carrying trace with no physical connection. The magnetic concentrators “catch” the magnetic field generated by current flowing through the primary trace and concentrate it over 4 hall cells. The hall cells produce a voltage proportional to the sensed magnetic flux, and that signal is amplified and conditioned by the ASIC making the output voltage directly proportional to the primary current through the trace underneath the sensor.